Power Circuits
With ignition off. Disconnect FBC control unit connector(s). Use a DVOM to probe FBC control unit terminal connector. Check that battery voltage is present at FBC control unit terminal A1 (back-up power). Turn ignition on and check that battery voltage is present at terminals A2 and A3. See appropriate wiring diagram in WIRING DIAGRAMS article. Repair circuits as required.