LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Hyundai >> 1993 >> Excel GS, Standard >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes >> Diagnostic Tests >> Code 11, 59 - Heated Oxygen Sensor Failure >> Scan Tester Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Scan Tester Procedure

Access scan tester service data item No. 11. Tester should display sensor voltage. Ensure engine is at normal operating temperature. See HO2S OPERATING VOLTAGE SPECIFICATIONS  table.

HO2S OPERATING VOLTAGE SPECIFICATIONS

Engine RPM Output (Volts)
750 .4 Or Less
2000 .6-1.0
4000 To 750 (1) .2 Or Less
750 To 4000 (2) .6-1.0
(1) Sudden deceleration.
(2) Sudden acceleration.