ECM Control Relay Test (Accent)
- Locate and remove ECM control relay, see ENGINE CONTROL RELAY LOCATION table. Using fused jumper wire, apply battery voltage to relay terminal No. 2. Using second fused jumper wire, ground relay terminal No. 4 (component side). See Figure, and go to next step.