No-Load Test
- Place the starter motor in a vise equipped with soft jaws and connect a fully charged 12 volt battery to starter motor as follows:
- Connect a test ammeter (100 amp scale) and carbon pile rheostat as shown is the illustration.
- Connect a voltmeter (15 volt scale) across starter motor.
- Rotate carbon pile to the off position.
- Connect the battery cable from battery's negative post to the starter motor body.
See Fig 1 .
- Adjust until battery voltage shown on the voltmeter reads 11 volts.
- Confirm that the maximum amperage is within the specifications and that the starter motor turns smoothly and freely. For specifications, see STARTER SPECIFICATIONS .