No-Load Test
- Place starter in soft-jaw vise. Rotate carbon pile rheostat to OFF position. Connect fully charged 12-volt battery, remote switch, voltmeter (15-volt scale), ammeter (100-amp scale), and carbon pile rheostat as shown. See Fig 1
.
- Rotate carbon pile to the OFF position.
- Connect the battery cable from battery's negative post to the starter motor body.
- Adjust carbon pile rheostat until voltmeter indicates 11 volts.
- Confirm that the maximum amperage and minimum RPM is within specification and that the starter motor turns smoothly and freely. See STARTER SPECIFICATIONS
.
Courtesy of HYUNDAI MOTOR CO.