Load Test
NOTE:
If the battery has been on a charge, remove surface charge by connecting a 300 amp load for 15 seconds. If necessary, refer to battery load tester manual for additional instructions.
- Connect the load tester clamps to the battery terminals.
- Connect voltmeter and apply specified load.
- Read voltage after load has been applied for 15 seconds.
- Disconnect the load.
- Compare voltage reading with minimum specification and replace battery if battery test voltage is below that shown in the voltage table. See BATTERY LOAD TEST SPECIFICATIONS table.
NOTE:
Specified load should be half of the CCA rating of the battery being tested.
BATTERY LOAD TEST SPECIFICATIONS (1)
| Temperature - °F (°C) | Minimum Voltage | ||
|---|---|---|---|
| 70 (20) | 9.6 | ||
| 60 (16) | 9.5 | ||
| 50 (10) | 9.4 | ||
| 40 (4) | 9.3 | ||
| 30 (-1) | 9.1 | ||
| 20 (-7) | 8.9 | ||
| 10 (-12) | 8.7 | ||
|
|||