1. Problem Verification
- Connect a Hi-Scan (Pro) to the data link connector.
- Turn ignition switch to ON position and monitor FTPS voltage signals.
- Specification: approximately 2.5V at idle
Is voltage within specification?
No: Go to next step.
Yes: Problem is intermittent or was repaired and engine control module memory was not cleared. Proceed with intermittent problem procedure.