A/C PRESSURE TRANSDUCER

INSPECTION




1. Measure the pressure of high pressure line by measuring voltage output between NO. 1 and NO. 2 terminals.
2. Inspect the voltage value whether it is sufficient to be regular value or not.

Voltage = 0100878835 * Pressure + 0.5 [kgf/sq.cm]

3. If the measured voltage value is not specification, replace the A/C pressure transducer.

Error range : ± 2.5%