LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Hyundai >> 2010 >> Azera GLS >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> General Information - Fuel System >> Troubleshooting >> Basic Troubleshooting >> Connector Inspection Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Connector Inspection Procedure

  1. Handling of Connector
    1. Never pull on the wiring harness when disconnecting connectors.
      Fig 1: Precaution - Never Pull On Wiring Harness When Disconnecting Connectors
      G06805015Courtesy of HYUNDAI MOTOR CO.
    2. When removing the connector with a lock, press or pull locking lever.
      Fig 2: Pressing Or Pull Connector Locking Lever
      G06805016Courtesy of HYUNDAI MOTOR CO.
    3. Listen for a click when locking connectors. This sound indicates that they are securely locked.
      Fig 3: Listening For Click When Locking Connectors
      G06805017Courtesy of HYUNDAI MOTOR CO.
    4. When a tester is used to check for continuity, or to measure voltage, always insert tester probe from wire harness side.
      Fig 4: Inserting Tester Probe From Wire Harness Side
      G06805018Courtesy of HYUNDAI MOTOR CO.
    5. Check waterproof connector terminals from the connector side. Waterproof connectors cannot be accessed from harness side.
      Fig 5: Checking Waterproof Connector Terminals From Connector Side
      G06805019Courtesy of HYUNDAI MOTOR CO.
      NOTE:
      • Use a fine wire to prevent damage to the terminal.
      • Do not damage the terminal when inserting the tester lead.
  2. Checking Point for Connector
    1. While the connector is connected:

      Hold the connector, check connecting condition and locking efficiency.

    2. When the connector is disconnected:

      Check missed terminal, crimped terminal or broken core wire by slightly pulling the wire harness.

      Visually check for rust, contamination, deformation and bend.

    3. Check terminal tightening condition:

      Insert a spare male terminal into a female terminal, and then check terminal tightening conditions.

    4. Pull lightly on individual wires to ensure that each wire is secured in the terminal.
      Fig 6: Pulling Lightly On Individual Wires To Ensure That Each Wire Is Secured In Terminal
      G06805020Courtesy of HYUNDAI MOTOR CO.
  3. Repair Method of Connector Terminal
    1. Clean the contact points using air gun and/or shop rag.
      NOTE: Never use sand paper when polishing the contact points, otherwise the contact point may be damaged.
    2. In case of abnormal contact pressure, replace the female terminal.