Repair Procedures: Installation
- Installation is the reverse of removal.
CAUTION:
After replacement or reinstallation procedure of the valve body assembly, must perform procedures below.
- Continue to apply liquid gasket at application points at the valve body cover with Ø2.5mm (0.0984in.) thickness.
Liquid gasket Part name:
Threebond 1281B or LOCTITE FMD-546
- Adding automatic transaxle fluid. (Refer to "REPAIR PROCEDURES " in this group.)