Repair Procedures: Removal
- Set room side lever and T/M side lever to "N" position.
- Remove the battery and the battery tray. (Refer to REMOVAL AND INSTALLATION .)
- Remove the air cleaner assembly. (Refer to INTAKE MANIFOLD .)
- Remove the shift cable mounting nut (B).
Tightening torque:
8.8 ~ 13.7 N.m (0.9 ~ 1.4 kgf.m, 6.5 ~ 10.1 lb-ft)
- Disconnect the inhibitor switch connector (A).
- Remove the manual control lever (A) and the washer (B) after removing a nut (C).
CAUTION: When installing, fix the manual control lever and the inhibitor switch with Ø5mm (0.1969in.) fixing jig.
And then tighten the inhibitor assembly mounting bolts.
- Remove the inhibitor assembly (A) after removing the bolts (2ea).
Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
CAUTION: When installing, tighten the inhibitor assembly mounting bolt lightly.