Repair procedures: Installation
- Installation is the reverse of removal.CAUTION: If the oil seal on the transaxle case side is damaged and fluid is leaking, replace the oil seal with a new unit. When installing the new oil seal, use the specialized tool (oil seal installer, 09452-26100).NOTE: After replacement or reinstallation procedure of the automatic transaxle assembly, perform procedures below.
- Adding automatic transaxle fluid.
(Refer to "Hydraulic system (FLUID )" )
- After servicing or replacing the automatic transaxle TCM, clear the diagnostic trouble codes (DTC) using the GDS tool.
Diagnostic trouble codes (DTC) cannot be cleared by disconnecting the battery.
- When replacing the automatic transaxle and TCM, reset the diagnostic trouble code by using GDS.
- Delete statement, use the GDS as possible.
- When replacing the automatic transaxle, reset the automatic transaxle's values by using the GDS, A/T menu, "Option Treatment" and "Resetting Auto T/A Values".
- Perform TCM learning after replacing the transaxle to prevent slow transaxle response, jerky acceleration and jerky startup.
(Refer to "Automatic transaxle control system (REPAIR PROCEDURES )" )
- Adding automatic transaxle fluid.