Torque Converter Control Solenoid Valve (T/CON_VFS): Installation
- Installation is the reverse of removal.NOTE: After replacement or reinstallation procedure of the valve body assembly, must perform procedures below.
- Continue to apply liquid gasket at application points at the valve body cover with Ø 2.5 mm (0.0984 in.) thickness.
Liquid gasket Part name:
Threebond 1281B or LOCTITE FMD-546
- Adding automatic transaxle fluid.
- Perform TCM learning after replacing the automatic transaxle to prevent slow automatic transaxle response, jerky acceleration and jerky startup (Refer to TCM LEARNING ).
- Continue to apply liquid gasket at application points at the valve body cover with Ø 2.5 mm (0.0984 in.) thickness.