Repair Procedures: Installation
- Installation is the reverse of removal.CAUTION: If the oil seal on the transaxle case side is damaged and fluid is leaking, replace the oil seal with a new unit. When installing the new oil seal, use the specialized tool (oil seal installer, 09453-3L240).NOTE: After replacement or reinstallation procedure of the automatic transaxle assembly, must perform procedures below.
- Adding automatic transaxle fluid.
(Refer to "FLUID ")
- After replacing the automatic transaxle, clear the Diagnostic Trouble Code (DTC) using the GDS tool. DTC cannot be cleared by disconnecting the battery.
- When replacing the automatic transaxle, reset the automatic transaxle's values by using the GDS.
- Perform TCM learning after replacing the transaxle to prevent slow transaxle response, jerky acceleration and jerky startup.
(Refer to Automatic Transaxle Control System - "REPAIR PROCEDURES ")
- Adding automatic transaxle fluid.