Manifold Absolute Pressure Sensor (MAPS): Specifications: Specification
| Pressure [kPa (kgf/cm2
, psi)] |
Output Voltage (V) |
| 10 (0.10, 1.45) |
0.5 |
| 20 (0.20, 2.9) |
0.88 |
| 30 (0.30, 4.35) |
1.26 |
| 40 (0.40, 5.80) |
1.64 |
| 50 (0.51, 7.25) |
2.02 |
| 60 (0.61, 8.70) |
2.4 |
| 70 (0.71, 10.15) |
2.79 |
| 80 (0.82, 11.60) |
3.17 |
| 100 (1.02, 14.50) |
3.93 |
| 115 (1.17, 16.68) |
4.5 |