Repair Procedures: Installation
NOTE:
- When replacing the Electric WGT Control Actuator, perform the rod adjustment procedure.
- When install the electric WGT control actuator, do not reuse a C-Ring.
- Install in the reverse order of removal.
Electric WGT control actuator installation:
11.8 - 13.7 N.m (1.2 - 1.4 kgf.m, 8.7 - 10.1 lb-ft)