TCM adaptive values learning procedure
- P range learning (learning condition: Intelligent Variable Transmission Fluid (IVTF) temperature: 30 - 90°C (86 - 194° F), shift lever P range, brake off)
- Start the engine after checking for the IVTF temperature in state of IG ON.
- Engine RPM will rise to approximately 1000 RPM after starting the engine.
- After 30 seconds to 2 minutes, the learning is completed when the engine RPM reaches the IDLE level.
(Learning completion can be confirmed from the "Sensor Data" of diagnostic tool)
NOTE:- Do not operate the shift lever, step on the accelerator pedal or brakes during P-step learning. (If it is operated during learning, perform it again after turning off the ignition switch.)