Sensor Range Charts
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
COOLANT TEMPERATURE SENSOR RESISTANCE
| Temperature - °F (°C) |
Ohms |
| 68 (20) |
2100-2900 |
| 122 (50) |
680-1000 |
| 176 (80) |
300-330 |
EGR TEMPERATURE SENSOR RESISTANCE
| Temperature - °F (°C) |
Ohms |
| 212 (100) |
76,770-93,830 |
FUEL TEMPERATURE SENSOR RESISTANCE (M30 & Q45)
| Temperature - °F (°C) |
Ohms |
| 68 (20) |
2100-2900 |
| 122 (50) |
680-1000 |
| 176 (80) |
300-330 |
HEATED OXYGEN SENSOR VOLTAGE
| Condition |
Volts |
| Lean |
0-0.3 |
| Rich |
0.6-1.0 |
CLOSED & WIDE OPEN THROTTLE SWITCH CONTINUITY
(G20)
| Position |
Reading |
| Closed Throttle |
Blue/Orange & White Green |
| Wide Open Throttle |
Blue/Orange & Blue Red |
CLOSED THROTTLE POSITION SWITCH CONTINUITY (J30 & Q45)
| Position |
Reading |
| Closed Throttle |
Continuity |
| Open Throttle |
No Continuity |
THROTTLE POSITION SENSOR RESISTANCE
| Position |
Ohms |
| G20 |
| Closed Throttle |
2000 |
| Partially Open |
2000-10,000 |
| Wide Open Throttle |
10,000 |
| J30 |
| Closed Throttle |
1700 |
| Partially Open |
1700-10500 |
| Wide Open Throttle |
10500 |
| Q45 |
| Closed Throttle |
700 |
| Partially Open |
700-5000 |
| Wide Open Throttle |
5000 |
MASS AIRFLOW SENSOR VOLTAGE (LOW RPM)
| Application |
Terminal No |
Volts |
| G20 |
"A" |
1.3-1.7 |
| J30 |
"B" |
1.0-1.4 |
| Q45 |
"1" |
1.0-1.4 |
MASS AIRFLOW SENSOR VOLTAGE (HIGH RPM)
| Application |
Terminal No |
Volts |
| G20 |
"A" |
1.7-2.1 |
| J30 |
"B" |
1.4-1.9 |
| Q45 |
"1" |
1.4-1.9 |
Courtesy of NISSAN MOTOR CO., U.S.A.