Component Inspection
CAUTION:
Always calibrate vacuum pump gauge when using it. Do not apply below -27.56 in. Hg (-93.3 kPa) or pressure over 29.92 in. Hg (101.3 kPa).
- Remove EVAP control system pressure sensor with harness connector connected.
- Remove EVAP control system pressure sensor from EVAP canister.
- Install a vacuum pump to EVAP control system pressure sensor.
- Turn ignition switch on and check output voltage between ECM terminal No. 32 and ground under following conditions:
- With no vacuum applied, voltage should be from 1.8-4.8 volts.
- With vacuum of -7.87 in. Hg (-26.7 mm Hg), voltage should be 2.1 to 2.5 volts less than value measured with no vacuum applied.
- If not to specification, replace EVAP control system pressure sensor.