Diagnostic Procedure
- Check Ground Connections
- Turn ignition switch OFF.
- Loosen and retighten three ground screws on the body. See Figure. Refer to GROUND INSPECTION .
OK or NG
- OK: Go to 2.
- NG: Repair or replace ground connections.
- Check EVAP Control System Pressure Sensor Connector For Water
- Disconnect EVAP control system pressure sensor harness connector. See Figure.
- Check sensor harness connector for water.
Water should not exist .
OK or NG
- OK: Go to 3.
- NG: Repair or replace harness connector.
- Check EVAP Control System Pressure Sensor
Refer to COMPONENT INSPECTION .
OK or NG
- OK: Go to 4.
- NG: Replace EVAP control system pressure sensor.
- Check Intermittent Incident
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
For wiring diagram, Refer to WIRING DIAGRAM .
- Inspection end