Diagnostic Procedure
- Check Ground Connections
- Turn ignition switch OFF.
- Loosen and retighten three ground screws on the body. See Figure. Refer to GROUND INSPECTION .
OK or NG
- OK: Go to 2.
- NG: Repair or replace ground connections.
- Check Connector
- Disconnect EVAP control system pressure sensor harness connector. See Figure.
- Check sensor harness connector for water.
Water should not exist .
OK or NG
- OK: Go to 3.
- NG: Repair or replace harness connector.
- Check EVAP Control System Pressure Sensor Power Supply Circuit
- Turn ignition switch ON.
- Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-II or tester.
Courtesy of NISSAN MOTOR CO., U.S.A.
Voltage: Approximately 5V
OK or NG
- OK: Go to 5.
- NG: Go to 4.
- Detect Malfunctioning Part
Check the following.
- Harness connectors B201, M81
- Harness connectors M82, F102
- Harness for open or short between EVAP control system pressure sensor and ECM
- Repair open circuit or short to ground or short to power in harness or connectors.
- Check EVAP Control System Pressure Sensor Ground Circuit For Open And Short
- Turn ignition switch OFF.
- Disconnect ECM harness connectors.
- Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal 67.
Refer to wiring diagram. See Figure.
Continuity should exist .
- Also check harness for short to ground and short to power.
OK or NG
- OK: Go to 7.
- NG: Go to 6.
- Detect Malfunctioning Part
Check the following.
- Harness connectors B201, M81
- Harness connectors M82, F102
- Harness for open or short between EVAP control system pressure sensor and ECM
- Repair open circuit or short to ground or short to power in harness or connectors.
- Check EVAP Control System Pressure Sensor Input Signal Circuit For Open And Short
- Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal 2.
Refer to wiring diagram. See Figure.
Continuity should exist .
- Also check harness for short to ground and short to power.
OK or NG
- OK: Go to 9.
- NG: Go to 8.
- Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal 2.
- Detect Malfunctioning Part
Check the following.
- Harness connectors B201, M81
- Harness connectors M82, F102
- Harness for open or short between EVAP control system pressure sensor and ECM
- Repair open circuit or short to ground or short to power in harness or connectors.
- Check EVAP Control System Pressure Sensor
Refer to COMPONENT INSPECTION .
OK or NG
- OK: Go to 10.
- NG: Replace EVAP control system pressure sensor.
- Check Intermittent Incident
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
- Inspection end