DTC Confirmation Procedure
NOTE:
If DTC confirmation procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.
With CONSULT-II
- Turn ignition switch ON and wait at least 1 second.
- Select DATA MONITOR mode with CONSULT-II. See Figure.
- Start engine and let it idle for 1 second.
- Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
- Repeat steps 3 and 4 for 4 times.
- If 1st trip DTC is detected, Go to DIAGNOSTIC PROCEDURE .
With GST