Diagnostic Procedure
- Check Ground Connections
- Turn ignition switch OFF.
- Loosen and retighten three ground screws on the body. See Figure. Refer to GROUND INSPECTION .
OK or NG
- OK: Go to 2.
- NG: Repair or replace ground connections.
- Check DTC With Unified Meter And A/C AMP
.
Refer to SELF-DIAGNOSTIC RESULTS .
OK or NG
- OK: Go to 3.
- NG: Go to FUEL LEVEL SENSOR SIGNAL INSPECTION .
- Check Fuel Tank Temperature Sensor Power Supply Circuit
- Turn ignition switch OFF.
- Disconnect fuel level sensor unit and fuel pump harness connector. See Figure.
- Turn ignition switch ON.
- Check voltage between fuel level sensor unit and fuel pump terminal 4 and ground with CONSULT-II or tester.
Courtesy of NISSAN MOTOR CO., U.S.A.
Voltage: Approximately 5V
OK or NG
- OK: Go to 5.
- NG: Go to 4.
- Detect Malfunctioning Part
Check the following.
- Harness connectors B1, M11
- Harness for open or short between ECM and fuel level sensor unit and fuel pump
- Repair harness or connector.
- Check Fuel Tank Temperature Sensor Ground Circuit For Open And Short
- Turn ignition switch OFF.
- Disconnect unified meter and A/C amp. harness connector.
- Check harness continuity between fuel level sensor unit and fuel pump terminal 5 and unified meter and A/C amp. terminal 36. Refer to wiring diagram. See Figure.
Continuity should exist .
- Also check harness for short to ground or short to power.
OK or NG
- OK: Go to 7.
- NG: Go to 6.
- Detect Malfunctioning Part
Check the following.
- Harness connectors B1, M11
- Harness for open or short between fuel level sensor unit and fuel pump and unified meter and A/C amp.
- Repair open circuit or short to ground or short to power in harness or connector.
- Check Fuel Tank Temperature Sensor
Refer to COMPONENT INSPECTION .
OK or NG
- OK: Go to 8.
- NG: Replace fuel level sensor unit.
- Check Intermittent Incident
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
- Inspection end