Consult-II Functions: Notes
NOTE:
- Do not use the "function test" for diagnosis. For more information, refer to the separate volume "CONSULT-II OPERATION MANUAL (Function Test)".
- When CONSULT-II is connected and communicating, ABS warning lamp, SLIP indicator lamp, and VDC OFF indicator lamp turn on, and when the communication is interrupted, the lamps will turn off after approximately 2 to 3 sec.
- When the self-diagnosis, data monitor, or active test functions are being executed, EBD, ABS, TCS, and VDC control is not performed.
- When using CONSULT-II to perform ABS actuator and electric unit (control unit) self-diagnosis, active test, work support, etc., first stop engine, connect CONSULT-II, and select "ABS".
- When an error is shown by the CONSULT-II SELF-DIAG RESULTS and CONSULT-II is used to perform an active test, an engine system malfunction may be shown, but restarting engine will return the status to normal.
- When data monitoring is executed by using CONSULT-II, a malfunction code may be indicated as the result of the real time diagnosis. In such a case, execute data monitoring in manual mode. Refer to CONSULT-II Operation Manual.