Procedure For Malfunction A
NOTE:
If engine will not start or stops soon, wait at least 10 seconds with engine stopped (Ignition switch ON) instead of running engine at idle speed.
With CONSULT-II
- Turn ignition switch ON.
- Select DATA MONITOR mode with CONSULT-II. See Figure .
- Start engine and warm it up to normal operating temperature.
- Run engine for at least 10 seconds at idle speed.
- If DTC is detected, go to DIAGNOSTIC PROCEDURE .
With GST
Follow the procedure With CONSULT-II above.