Testing Condition
Always perform test at a temperature of 5° C (41° F) or more .
With CONSULT-II
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and let it idle for at least 70 seconds.
- Select PURG FLOW P0441 of EVAPORATIVE SYSTEM in DTC CONFIRMATION mode with CONSULT-II.
- Touch START.
If COMPLETED is displayed, go to step 7.
- When the following conditions are met, TESTING will be displayed on the CONSULT-II screen. Maintain the conditions continuously until TESTING changes to COMPLETED. (It will take at least 35 seconds.)
Courtesy of NISSAN MOTOR CO., U.S.A.
If TESTING is not changed for a long time, retry from step 2 .
- Make sure that OK is displayed after touching SELF-DIAG RESULTS. If NG is displayed, Refer to DIAGNOSTIC PROCEDURE .