Diagnostic Procedure
- Check Ground Connections
- Turn ignition switch OFF.
- Loosen and retighten three ground screws on the body, see Figure
and Refer to GROUND INSPECTION
.
OK or NG
- OK: go to 2.
- NG: Repair or replace ground connections.
- Check EVAP Control System Pressure Sensor Connector For Water
- Disconnect EVAP control system pressure sensor harness connector. See Figure .
- Check sensor harness connector for water.
- Water should not exist .
OK or NG
- OK: go to 3.
- NG: Repair or replace harness connector.
- Check EVAP Control System Pressure Sensor
Refer to COMPONENT INSPECTION .
OK or NG
- OK: go to 4.
- NG: Replace EVAP control system pressure sensor.
- Check Intermittent Incident
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT . For Wiring Diagram, Refer to WIRING DIAGRAM .
- Inspection end