Testing Condition
Always perform test at a temperature of 5° C (41° F) or more .
With CONSULT-II
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Select DATA MONITOR mode with CONSULT-II. See Figure .
- Make sure that FUEL T/TEMP SE is more than 0° C (32° F).
- Start engine and wait at least 20 seconds.
- If 1st trip DTC is detected, go to DIAGNOSTIC PROCEDURE .
With GST
- Start engine and warm it up to normal operating temperature.
- Check that voltage between ECM terminal 107 (Fuel tank temperature sensor signal) and ground is less than 4.2V. See Figure .
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and wait at least 20 seconds.
- Select MODE 7 with GST.
If 1st trip DTC is detected, go to DIAGNOSTIC PROCEDURE .