DTC Confirmation Procedure
NOTE:
If DTC confirmation procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.
With CONSULT-II
- Turn ignition switch ON and wait at least 5 seconds.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON and select DATA MONITOR mode with CONSULT-II. See Figure .
- Start engine and let it idle for at least 1 minute.
- Repeat next procedures 3 times.
- Increase the engine speed up to 3,000 to 3,500 RPM and keep it for 2 minutes and 50 seconds to 3 minutes.
Never exceed 3 minutes .
- Fully released accelerator pedal and keep engine idle for about 5 seconds.
- Increase the engine speed up to 3,000 to 3,500 RPM and keep it for 2 minutes and 50 seconds to 3 minutes.
- If 1st trip DTC is detected, go to DIAGNOSTIC PROCEDURE
.
If 1st trip DTC is not detected, go to the next step.
- Repeat next procedure 20 times.
- Quickly increase the engine speed up to 4,000 to 4,500 RPM or more and keep it for 25 to 30 seconds.
- Fully released accelerator pedal and keep engine idle for at least 35 seconds.
- If 1st trip DTC is detected, go to DIAGNOSTIC PROCEDURE .
With GST
Follow the procedure With CONSULT-II above.