Testing Condition:
Before performing the following procedure, confirm that battery voltage is more than 10.5V with ignition switch ON.
With CONSULT-II
- Turn ignition switch ON.
- Select DATA MONITOR mode with CONSULT-II. See Figure .
- Crank engine for at least 2 seconds and run it for at least 5 seconds at idle speed.
- If 1st trip DTC is detected, go to DIAGNOSTIC PROCEDURE . If 1st trip DTC is not detected, go to next step.
- Maintaining engine speed at more than 1,000 rpm for at least 5 seconds.
- If 1st trip DTC is detected, go to DIAGNOSTIC PROCEDURE .
With GST
Follow the procedure With CONSULT-II.