With GST
NOTE:
Start from step 11
, if it is possible to confirm that the fuel cannot be drained by 30l (7-7/8 US gal, 6-5/8 Imp gal) in advance.
- Prepare a fuel container and a spare hose.
- Release fuel pressure from fuel line, refer to FUEL PRESSURE RELEASE .
- Remove the fuel feed hose on the fuel level sensor unit.
- Connect a spare fuel hose where the fuel feed hose was removed.
- Turn ignition switch OFF.
- Set voltmeters probe between ECM terminal 69 (fuel level sensor signal) and ground.
- Turn ignition switch ON.
- Check voltage between ECM terminal 69 and ground and note it.
- Drain fuel by 30l (7-7/8 US gal, 6-5/8 Imp gal) from the fuel tank using proper equipment.
- Fill fuel into the fuel tank for 30l (7-7/8 US gal, 6-5/8 Imp gal).
- Confirm that the voltage between ECM terminal 69 and ground changes more than 0.03V during step 8 - 10.
- If NG, check component of fuel level sensor, refer to FUEL LEVEL SENSOR UNIT CHECK .