Diagnostic Procedure
- CHECK ECM POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check voltage between ECM terminal 67 and ground with CONSULT-II or tester.
Voltage: Battery voltage
OK or NG
- OK: GO TO 3 .
- NG: GO TO 2.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E15, F18
- Joint connector-13
- 15A fuse
- Harness for open or short between ECM and fuse
- : Repair or replace hardness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
OK or NG
- OK: GO TO 4.
- NG: Repair or replace hardness or connectors.
- PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT-II
- Turn ignition switch ON.
- Select SELF DIAG RESULTS mode with CONSULT-II.
- Touch ERASE.
- Perform DTC CONFIRMATION PROCEDURE .
- Is the 1st trip DTC P1065 displayed again?
With GST
- Turn ignition switch ON.
- Select MODE 4 with GST.
- Touch ERASE.
- Perform DTC CONFIRMATION PROCEDURE .
- Is the 1st trip DTC P1065 displayed again?
Yes or No
- YES: GO TO 5.
- NO: INSPECTION END
- REPLACE ECM
- Replace ECM.
- Perform initialization of IVIS (NATS) system and registration of all IVIS (NATS) ignition key IDs. Refer to IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM - NATS) .
- Perform ACCELERATOR PEDAL RELEASED POSITION LEARNING .
- Perform THROTTLE VALVE CLOSED POSITION LEARNING .
- Perform IDLE AIR VOLUME LEARNING .
- : INSPECTION END.