Overall Function Check
WITH GST
Use this procedure to check the overall function of the EVAP very small leak function. During this check, a DTC might not be confirmed.
CAUTION:
- Never use compressed air, doing so may damage the EVAP system.
- Do not start engine.
- Do not exceeded 4.12 kPa (0.042 kg/cm2 , 0.6 psi).
- Attach the EVAP service port adapter securely to the EVAP service port. See Figure .
- Set the pressure pump and a hose.
- Also set a vacuum gauge via 3-way connector and a hose.
- Turn ignition switch ON.
- Connect GST and select mode 8.
- Using mode 8 control the EVAP canister vent control valve (close) and vacuum cut valve bypass valve (open).
- Apply pressure and make sure the following conditions are satisfied.
Pressure to be applied: 2.7 kPa (20 mmHg, 0.79 inHg) Time to be waited after the pressure drawn in to the EVAP system and the pressure to be dropped: 60 seconds and the pressure should not be dropped more than 0.4 kPa (3 mmHg, 0.12 inHg)
If NG, go to DIAGNOSTIC PROCEDURE .
If OK, go to next step.
- Disconnect GST.
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Restart engine and let it idle for 90 seconds.
- Keep engine speed at 2,000 rpm for 30 seconds.
- Turn ignition switch OFF.NOTE: For more information, refer to GST instruction manual.