7. Check EVAP Control System Pressure Sensor Input Signal Circuit For Open And Short
- Check harness continuity between ECM terminal 110 and EVAP control system pressure sensor terminal 2.
Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 9. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SHIELD CIRCUIT FOR OPEN AND SHORT .
- NG: GO TO 8.