16. Check EVAP Control System Pressure Sensor Shield Circuit For Open And Short
- Disconnect harness connectors B401, B251.
- Check continuity between harness connector B251 terminal 5 and ground.
Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to power.
- Then reconnect harness connectors B401, B251.
OK or NG
- OK: GO TO 18. CHECK INTERMITTENT INCIDENT .