6. Check Fuel Level Sensor Input Signal Circuit For Open And Short
- Disconnect ECM harness connector.
- Check harness continuity between the following;
ECM terminal 119 and "fuel level sensor unit and fuel pump" terminal 5,
ECM terminal 107 and "fuel level sensor unit and fuel pump" terminal 6.
Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 8. CHECK FUEL LEVEL SENSOR .
- NG: GO TO 7.