2. Check Fuel Level Sensor Ground Circuit For Open And Short
- Disconnect ECM harness connector.
- Disconnect combination meter harness connector.
- Check harness continuity between ECM terminal 107 and combination meter terminal 31. Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to power.
OK or NG
- OK: GO TO 4. CHECK INTERMITTENT INCIDENT .
- NG: GO TO 3.