5. Check Refrigerant Pressure Sensor Ground Circuit For Open And Short
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between refrigerant pressure sensor terminal 3 and ECM terminal 89.
Refer to Wiring Diagram .
Continuity should exist.
- Also check harness for short to ground or short to power.
OK or NG
- OK: GO TO 6.
- NG: GO TO 5.