Without CONSULT-II
- Lift up the vehicle.
- Start engine and warm it up to normal operating temperature.
- Make sure that power valve actuator rod moves when changing the selector lever position to N and D alternately.
OK or NG
- OK: INSPECTION END
- NG (With CONSULT-II): GO TO 2.
- NG (Without CONSULT-II): GO TO 3. CHECK VACUUM EXISTENCE .