7. Check EVAP Control System Pressure Sensor Input Signal Circuit For Open And Short
- Check harness continuity between ECM terminal 110 and EVAP control system pressure sensor terminal 2.
Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK : GO TO 9. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR .
NG : GO TO 8.