5. Check MAF Sensor Input Signal Circuit For Open And Short
- Check harness continuity between MAF sensor terminal 1 and ECM terminal 91.
Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK : GO TO 6.
NG : Repair open circuit or short to ground or short to power in harness or connectors.