2. Check Fuel Level Sensor Ground Circuit For Open And Short
- Disconnect ECM harness connector.
- Disconnect combination meter harness connector.
- Check harness continuity between ECM terminal 107 and combination meter terminal 29. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK: GO TO 4.
NG: GO TO 3.