Procedure For Malfunction A
With CONSULT-II
- Turn ignition switch ON.
- Select "DATA MONITOR" mode with CONSULT-II.
- Confirm "RADIATOR TEMP" indicates less than 80°C (176°F). If not, cool down the engine.
- Start engine and let it idle for at least 5 seconds.
- If DTC is detected, go to DIAGNOSTIC PROCEDURE .
With GST
- Turn ignition switch ON.
- Set voltmeter probes between ECM terminal 122 (radiator coolant temperature sensor signal) and ground.
- Check the voltage should be above 1.23V.
If not, cool down the engine.
- Start engine and let it idle for at least 5 seconds.
- If DTC is detected, go to DIAGNOSTIC PROCEDURE .