With CONSULT-II
- Attach the EVAP service port adapter securely to the EVAP service port.
- Also attach the pressure pump and hose to the EVAP service port adapter.
- Turn ignition switch ON.
- Select the "EVAP SYSTEM CLOSE" of "WORK SUPPORT MODE" with CONSULT-II.
- Touch "START". A bar graph (Pressure indicating display) will appear on the screen.
Courtesy of NISSAN MOTOR CO., U.S.A.
- Apply positive pressure to the EVAP system until the pressure indicator reaches the middle of the bar graph.
Courtesy of NISSAN MOTOR CO., U.S.A.
- Remove EVAP service port adapter and hose with pressure pump.
- Locate the leak using a leak detector. Refer to EVAPORATIVE EMISSION LINE DIAGRAM
.