11. Check Condenser Circuit For Open And Short
- Turn ignition switch OFF.
- Disconnect condenser harness connector.
- Check harness continuity between the following;
ECM terminal 12 and condenser terminal 1,
Condenser terminal 2 and ground.
Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK: GO TO 12.
NG: Repair open circuit or short to ground or short to power in harness or connectors.