7. Check Refrigerant Pressure Sensor Input Signal Circuit For Open And Short
- Check harness continuity between ECM terminal 88 and refrigerant pressure sensor terminal 2.
Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK: GO TO 9.
NG: GO TO 8.