With Consult-II
- Reconnect harness connectors disconnected.
- Turn ignition switch ON.
- Perform "VIAS SOL VALVE " in "ACTIVE TEST" mode.
- Check air passage continuity and operation delay time under the following conditions.
CONDITION VIAS SOL VALVE AND AIR PASSAGE CONTINUITY REFERENCE CHART
| Condition VIAS SOL VALVE | Air passage continuity between A and B | Air passage continuity between A and C |
|---|---|---|
| ON | Yes | No |
| OFF | No | Yes |
Operation takes less than 1 second.