Operation Procedure

  1. Perform "CONSULT-II Starting Procedure". Refer to "CONSULT-II START PROCEDURE ".
  2. Touch "SELECT TEST ITEM" is displayed.
  3. Touch necessary test item.
    Fig 1: CONSULT II Display - ACTIVE TEST
    G05211843
  4. While "MAIN SIGNALS" indication is inverted, touch "START".
  5. "ACTIVE TEST" screen will be displayed so perform the following test.
    NOTE:
    • When active test is performed while depressing the pedal, the pedal depression amount will change. This is normal. (Only solenoid valve and ABS motor)
    • "TEST IS STOPPED" is displayed 10 seconds after operation start.
    • After "TEST IS STOPPED" is displayed, to perform test again, touch "BACK" and repeat step  3.