DTC Confirmation Procedure
- INSPECTION START
Do you have CONSULT-III?
Do you have CONSULT-III?
YES: GO TO 2.
NO: GO TO 6.
- PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5°C (41°F) or more.
GO TO 3.
- PERFORM DTC CONFIRMATION PROCEDURE-I
With CONSULT-III
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and let it idle for at least 70 seconds.
- Select "PURG FLOW P0441" of "EVAPORATIVE SYSTEM" in "DTC WORK SUPPORT" mode with CONSULT-III.
- Touch "START".
Is "COMPLETED" displayed on CONSULT-III screen?
YES: GO TO 5.
NO: GO TO 4.
- PERFORM DTC CONFIRMATION PROCEDURE-II
When the following conditions are met, "TESTING" will be displayed on the CONSULT-III screen. Maintain the conditions continuously until "TESTING" changes to "COMPLETED". (It will take at least 35 seconds.)
DTC CONFIRMATION PROCEDURE-IISelector lever Suitable position VHCL SPEED SE 32 - 120 km/h (20 - 75 mph) ENG SPEED 500 - 3, 000 rpm B/FUEL SCHDL 1.3 - 9.0 msec COOLAN TEMP/S More than 0°C (32°F) CAUTION: Always drive vehicle at a safe speed.Is "COMPLETED" displayed on CONSULT-III screen?
YES: GO TO 5.
NO: Perform DTC CONFIRMATION PROCEDURE again. GO TO 3.
- PERFORM DTC CONFIRMATION PROCEDURE-III
Touch "SELF-DIAG RESULTS".
Which is displayed on CONSULT-III screen?
OK: INSPECTION END
NG: Go to "DIAGNOSIS PROCEDURE ".
- PERFORM COMPONENT FUNCTION CHECK
Perform component function check. Refer to "COMPONENT FUNCTION CHECK ".
NOTE: Use component function check to check the overall monitoring function of the EVAP control system purge flow monitoring. During this check, a 1st trip DTC might not be confirmed.Is the inspection result normal?
YES: INSPECTION END
NO: Go to "DIAGNOSIS PROCEDURE ".