Component Inspection
- CHECK FUEL FILLER CAP
- Turn ignition switch OFF.
- Remove fuel filler cap.
- Wipe clean valve housing.
- Install fuel filler cap adapter (commercial service tool) to fuel filler cap.
- Check valve opening pressure and vacuum.
Pressure: 15.3 - 20.0 kPa (0.156 - 0.204 kg/cm 2 , 2.22 - 2.90 psi)
Vacuum: -6.0 to -3.3 kPa (-0.061 to -0.034 kg/cm 2 , -0.87 to -0.48 psi)
Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- REPLACE FUEL FILLER CAP
Replace fuel filler cap.
CAUTION: Use only a genuine fuel filler cap as a replacement. If an incorrect fuel filler cap is used, the MIL may come on.INSPECTION END